Application: Reactor Systems Autoclaves, Pilot Systems, Mini Plant Systems, Scale up for Operational Development, Double wall reactors, Advanced-Flow Reactors, Distillation Systems, Material Testing, Combinational Chemistry, Semiconductor Industry, Vacuum Chambers.
Advantages & Functions
Hermetic circulation system ensures high accuracy of temperature and extends the lifespan of circulating liquid.
Operates over a wide temperature range from -100°C to +350°C without changing the cooling fluid.
Intelligent PID temperature control.
High stability and reproducibility of the process.
Plate heat exchanger improves heating and cooling efficiency.
Wide cooling power range from 0.5 to 500 kW.
Brilliant 4 inch, 7 inch, 10 inch TFT touch screen with graphic display available.
Comprehensive warning and safety functions.
Rapid cooling down from high temperature (from 300°C).
Control software is available for communication within 200 meters. (Optional)
Incredibly compact design.
Structure Design A fully closed piping design, high efficiency plate heat exchanger used to reduce the demand for thermal fluid utilization while providing the system to achieve rapid ups and downs in temperature. The whole system is a closed liquid circulation system with an expansion container, expansion of the container, and liquid circulation is adiabatic, it will not involve liquid circulation, only mechanical connection, regardless of the temperature being high or low, the tank temperature is limited to 60°C. The advantages by this design:
Only the heat conduction medium in the expansion container touches the oxygen in the air. (The container temperature is limited to 60°C), therefore, during the process the risk of imbibing and volatilization of the heat conducting medium is reduced.
No volatilization of the heat conducting medium at high temperature.
No need to change the heat conducting medium. Continuous control the temperature range to -80°C~190°C, -70°C~220°C, -88°C~170°C, -55°C~250°C, -30°C~300°C without rising the pressure.
Display Function
All the kind of process control temperatures.
Liquid level of the heat conducting medium in the expansion vessel.
Indication working status of refrigeration system.
Indication working status of heater.
Indication working status of circulation pump.
Temperature control mode (materials and heat transfer medium).
Temperature upper limit and lower limit can be set.
Temperature difference between jacket & reactor material can be set.
Alarm when liquid is empty.
Refrigeration compressor can be set to operate manually or automatically.
Clear temperature curve displayed, it can be zoomed and exported to computer.
Recipe procedure set display
Alarm note display
Principle of process control Change the control settings of the method, respond as soon as possible in the process of the system lags behind, be the smallest system overshoot. Controlled by two PID (PID is a variable in each group) control loop structure, known as the two sets of control loops: the main circuit and from the circuit, the main control loop from the loop output as the settings. System with feed forward with PV, the master PID loop operation results of the PV output and feed forward signals as the composite of the settings from the control loop, through such control of the temperature gradient to ensure the accuracy of temperature control system.
High repeatability of results control  Â
Circulation Pump High temperature resistant low temperature magnetic drive pump or a leak-free high and low temperature shield-driven pump, reduce the risk of system leakage. At the same time the system has the advantages of low noise and big traffic flow.
Electronic Expansion Valve Wide temperature range of dynamic temperature control system with electronic expansion valve produced by Emerson company, It can monitor and adjust the number of steps (0~750 Steps / minute) into the motor, precise control the liquid volume from the refrigerant, Improve control accuracy.
Configuration Software (Optional)
All dynamic temperature control system HRHC-Series can be connected with the computer. You can install and record the picture of display on the computer via the configuration software.
Communication distance less than 200m.
Easily temperature setting
Real time control screen
Curve Records
Program selection
Alarm screen recording
Safety Protection Many additional features to ensure the safe operation of the system. For the operation to run not normally appear in the alarm in time and displayed on the touch screen. Phase sequence, leakage protection, refrigeration system high and low voltage protection, overload the pump, compressor overload, high and low level, two independent over-temperature protection, water protection, protection of the circulation line shut.
Connecting Pipe
Items
Temp. range
Interface port
Fluorine rubber hose
-30~200°C
Φ12*16 Φ16*22 Φ20* 26
Metal insulation pipe
-60~250°C
DN15 DN20 DN25 M24*1.5 M30*1.5 M38*1.5
Date Interface & Software Standard configuration:
Inputs of PT100 temperature sensor
USB data export interfaces
RS485 interface (MODBUS protocol)
Alarm contact output
Optional:
Inputs of 4 ~ 20mA temperature measurement
Inputs of 4 ~ 20mA temperature setting
Ethernet interface
RS232 interface (MODBUS protocol)
Computer operating software (Must be fitted with Ethernet interface)
External control box with touch screen display
Common Specifications:
Control mode: Feed forward PID, PLC control
Temperature control: Temperature of material and circulation liquid can be controlled and set
Program: 20 group programs, 45 segments for each group
Protocol: MODBUS RTU / RS 485 Interface
Temp. sensor: Circulation medium PT100, raw material PT100 (3 measuring points) 4~20mA (Optional)
Control panel: 7 inches color touch screen, temperature curve display & record
Safety: With self-diagnosis function; freezer overload protection; high-pressure switch, a variety of security features overload relays, thermal protection devices.
Closed loop system: Fully closed system, no oil mist at high temperature, low temperature do not absorb moisture in the air, the system does not increase the pressure because the high temperature, low temperature heat transfer medium in automatic replenishment operation.